Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Open Forum Infect Dis ; 10(12): ofad599, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38130595

RESUMEN

Background: Older age and chronic conditions are associated with severe influenza outcomes; however, data are only comprehensively available for adults ≥65 years old. Using data from the Influenza Hospitalization Surveillance Network (FluSurv-NET), we identified characteristics associated with severe outcomes in adults 18-49 years old hospitalized with influenza. Methods: We included FluSurv-NET data from nonpregnant adults 18-49 years old hospitalized with laboratory-confirmed influenza during the 2011-2012 through 2018-2019 seasons. We used bivariate and multivariable logistic regression to determine associations between select characteristics and severe outcomes including intensive care unit (ICU) admission, invasive mechanical ventilation (IMV), and in-hospital death. Results: A total of 16 140 patients aged 18-49 years and hospitalized with influenza were included in the analysis; the median age was 39 years, and 26% received current-season influenza vaccine before hospitalization. Obesity, asthma, and diabetes mellitus were the most common chronic conditions. Conditions associated with a significantly increased risk of severe outcomes included age group 30-39 or 40-49 years (IMV, age group 30-39 years: adjusted odds ratio [aOR], 1.25; IMV, age group 40-49 years: aOR, 1.36; death, age group 30-39 years: aOR, 1.28; death, age group 40-49 years: aOR, 1.69), being unvaccinated (ICU: aOR, 1.18; IMV: aOR, 1.25; death: aOR, 1.48), and having chronic conditions including extreme obesity and chronic lung, cardiovascular, metabolic, neurologic, or liver diseases (ICU: range aOR, 1.22-1.56; IMV: range aOR, 1.17-1.54; death: range aOR, 1.43-2.36). Conclusions: To reduce the morbidity and mortality associated with influenza among adults aged 18-49 years, health care providers should strongly encourage receipt of annual influenza vaccine and lifestyle/behavioral modifications, particularly among those with chronic medical conditions.

2.
MMWR Morb Mortal Wkly Rep ; 72(40): 1089-1094, 2023 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-37796744

RESUMEN

Adults aged ≥65 years remain at elevated risk for severe COVID-19 disease and have higher COVID-19-associated hospitalization rates compared with those in younger age groups. Data from the COVID-19-Associated Hospitalization Surveillance Network (COVID-NET) were analyzed to estimate COVID-19-associated hospitalization rates during January-August 2023 and identify demographic and clinical characteristics of hospitalized patients aged ≥65 years during January-June 2023. Among adults aged ≥65 years, hospitalization rates more than doubled, from 6.8 per 100,000 during the week ending July 15 to 16.4 per 100,000 during the week ending August 26, 2023. Across all age groups, adults aged ≥65 years accounted for 62.9% (95% CI = 60.1%-65.7%) of COVID-19-associated hospitalizations, 61.3% (95% CI = 54.7%-67.6%) of intensive care unit admissions, and 87.9% (95% CI = 80.5%-93.2%) of in-hospital deaths associated with COVID-19 hospitalizations. Most hospitalized adults aged ≥65 years (90.3%; 95% CI = 87.2%-92.8%) had multiple underlying conditions, and fewer than one quarter (23.5%; 95% CI = 19.5%-27.7%) had received the recommended COVID-19 bivalent vaccine. Because adults aged ≥65 years remain at increased risk for COVID-19-associated hospitalization and severe outcomes, guidance for this age group should continue to focus on measures to prevent SARS-CoV-2 infection, encourage vaccination, and promote early treatment for persons who receive a positive SARS-CoV-2 test result to reduce their risk for severe COVID-19-associated outcomes.


Asunto(s)
COVID-19 , Humanos , Adulto , Estados Unidos/epidemiología , COVID-19/epidemiología , COVID-19/terapia , SARS-CoV-2 , Hospitalización , Unidades de Cuidados Intensivos , Vacunación
3.
J Biomech ; 153: 111599, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37137272

RESUMEN

In the flexed end-of-range position (e.g., during slumped sitting), the trunk is passively stabilized. Little is known about the biomechanical consequence of posterior approaches on passive stabilization. The aim of this study is to investigate the effect of posterior surgical interventions on local and distant spinal regions. While being fixed at the pelvis, five human torsos were passively flexed. The change in spinal angulation at Th4, Th12, L4 and S1 was measured after level-wise longitudinal incisions of the thoracolumbar fascia, the paraspinal muscles, horizontal incisions of the inter- & supraspinous ligaments (ISL/SSL) and horizontal incision of the thoracolumbar fascia and the paraspinal muscles. Lumbar angulation (Th12-S1) was increased by 0.3° for fascia, 0.5° for muscle and 0.8° for ISL/SSL-incisions per lumbar level. The effect of level-wise incisions at the lumbar spine was 1.4, 3.5 and 2.6 times greater compared to thoracic interventions for fascia, muscle and ISL/SSL respectively. The combined midline interventions at the lumbar spine were associated with 2.2° extension of the thoracic spine. Horizontal incision of the fascia increased spinal angulation by 0.3°, while horizontal muscle incision resulted in a collapse of 4/5 specimens. The thoracolumbar fascia, the paraspinal muscle and the ISL/SSL are important passive stabilizers for the trunk in the flexed end-of-range position. Lumbar interventions needed for approaches to the spine have a larger effect on spinal posture than thoracic interventions and the increase of spinal angulation at the level of the intervention is partially compensated at the neighboring spinal regions.


Asunto(s)
Vértebras Lumbares , Vértebras Torácicas , Humanos , Vértebras Torácicas/cirugía , Vértebras Torácicas/fisiología , Vértebras Lumbares/cirugía , Vértebras Lumbares/fisiología , Fascia/fisiología , Ligamentos Articulares , Postura/fisiología , Fenómenos Biomecánicos/fisiología
4.
Pathog Glob Health ; 117(2): 104-119, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-35950264

RESUMEN

Health Technology Assessment (HTA) is a multidisciplinary tool to inform healthcare decision-making. HTA has been implemented in high-income countries (HIC) for several decades but has only recently seen a growing investment in low- and middle-income countries. A scoping review was undertaken to define and compare the role of HTA in least developed and lower middle-income countries (LLMIC). MEDLINE and EMBASE databases were searched from January 2015 to August 2021. A matrix comprising categories on HTA objectives, methods, geographies, and partnerships was used for data extraction and synthesis to present our findings. The review identified 50 relevant articles. The matrix was populated and sub-divided into further categories as appropriate. We highlight topical aspects of HTA, including initiatives to overcome well-documented challenges around data and capacity development, and identify gaps in the research for consideration. Those areas we found to be under-studied or under-utilized included disinvestment, early HTA/implementation, system-level interventions, and cross-sectoral partnerships. We consider broad practical implications for decision-makers and researchers aiming to achieve greater interconnectedness between HTA and health systems and generate recommendations that LLMIC can use for HTA implementation. Whilst HIC may have led the way, LLMIC are increasingly beginning to develop HTA processes to assist in their healthcare decision-making. This review provides a forward-looking model that LLMIC can point to as a reference for their own implementation. We hope this can be seen as timely and useful contributions to optimize the impact of HTA in an era of investment and expansion and to encourage debate and implementation.


Asunto(s)
Países en Desarrollo , Evaluación de la Tecnología Biomédica , Evaluación de la Tecnología Biomédica/métodos , Tecnología Biomédica
5.
Spine J ; 22(12): 2066-2071, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35964832

RESUMEN

BACKGROUND CONTEXT: The effect of the posterior midline approach to the lumbar spine, relevance of inter- and supraspinous ligament (ISL&SSL) sparing, and potential of different wound closure techniques are largely unknown despite their common use. PURPOSE: The aim of this study was to quantify the effect of the posterior approach, ISL&SSL resection, and different suture techniques. STUDY DESIGN: Biomechanical cadaveric study. METHODS: Five fresh frozen human torsi were stabilized at the pelvis in the erect position. The torsi were passively loaded into the forward bending position and the sagittal angulation of the sacrum, L4 and T12 were measured after a level-wise posterior surgical approach from L5/S1 to T12/L1 and after a level-wise ISL&SSL dissection of the same sequence. The measurements were repeated after the surgical closure of the thoracolumbar fascia with and without suturing the fascia to the spinous processes. RESULTS: Passive spinal flexion was increased by 0.8±0.3° with every spinal level accessed by the posterior approach. With each additional ISL&SSL resection, a total increase of 1.6±0.4° was recorded. Suturing of the thoracolumbar fascia reduced this loss of resistance against lumbar flexion by 70%. If the ISL&SSL were resected, fascial closure reduced the lumbar flexion by 40% only. In both settings, suturing the fascia to the spinous processes did not result in a significantly different result (p=.523 and p=.730 respectively). CONCLUSION: Each level accessed by a posterior midline approach is directly related to a loss of resistance against passive spinal flexion. Additional resection of ISL&SSL multiplies it by a factor of two. CLINICAL SIGNIFICANCE: The surgical closure of the thoracolumbar fascia can reduce the above mentioned loss of resistance partially. Suturing the fascia to the spinal processes does not result in improved passive stability.


Asunto(s)
Vértebras Lumbares , Articulación Cigapofisaria , Humanos , Fenómenos Biomecánicos , Vértebras Lumbares/cirugía , Región Lumbosacra , Ligamentos Articulares
6.
J Ultrasound Med ; 41(11): 2867-2875, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35302664

RESUMEN

OBJECTIVES: To compare medial meniscal extrusion on weight-bearing ultrasound (US) with supine US and magnetic resonance (MR) imaging correlating with meniscal pathology and reported symptoms. METHODS: IRB approved study with informed consent. Patients obtaining routine knee MR imaging for suspected knee pathology were prospectively evaluated with supine and weight-bearing US of the medial meniscus. Meniscal extrusion was measured independently by two fellowship-trained musculoskeletal radiologists. Correlation was made to presence or absence of meniscal degeneration or tear on MR imaging, as well as reported symptoms. Statistical significance was calculated via intraclass correlation coefficient (ICC) and analysis of variance (ANOVA). RESULTS: Ninety-nine knees from 95 subjects (50 males, 45 females; mean age 45 ± 15 years) were included. Mean medial meniscal extrusion measured at US for a normal meniscus (n = 36) was 0.8 mm when supine, increasing to 1.6 mm on weight-bearing. Mean meniscal extrusion in subjects with mucoid degeneration (n = 20) and those with meniscal tears (n = 43) was 1.6 mm, increasing to 2.3 mm with weight bearing. Inter-reader reliability showed ICC values of 0.853 to 0.940. There was a significant difference in medial meniscal extrusion comparing subjects with a normal medial meniscus at magnetic resonance imaging (MRI) and subjects with either meniscal degeneration or tear. There was no significant difference in degree of meniscal extrusion between subjects with meniscal degeneration or tear. There was trend of worsening symptoms and increasing functional limitations moving from normal meniscus to meniscal degeneration to meniscal tear. CONCLUSIONS: A normal meniscus shows lesser mobility between supine and upright position, than a pathologic meniscus. Both mucoid degeneration and meniscal tear demonstrate extrusion in the supine position, which increases with weight-bearing position.


Asunto(s)
Traumatismos de la Rodilla , Meniscos Tibiales , Masculino , Femenino , Humanos , Adulto , Persona de Mediana Edad , Meniscos Tibiales/diagnóstico por imagen , Meniscos Tibiales/patología , Soporte de Peso , Reproducibilidad de los Resultados , Ultrasonografía/métodos , Imagen por Resonancia Magnética/métodos , Rotura
7.
Invest Radiol ; 57(6): 387-398, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35025835

RESUMEN

OBJECTIVES: The aim of this study was to demonstrate the feasibility and efficacy of basic (increased receive bandwidth) and advanced (view-angle tilting [VAT] and slice-encoding for metal artifact correction [SEMAC]) techniques for metal-artifact reduction in ultra-high field 7-T magnetic resonance imaging (MRI). MATERIALS AND METHODS: In this experimental study, we performed 7-T MRI of titanium alloy phantom models composed of a spinal pedicle screw (phantom 1) and an intervertebral cage (phantom 2) centered in a rectangular LEGO frame, embedded in deionized-water-gadolinium (0.1 mmol/L) solution. The following turbo spin-echo sequences were acquired: (1) nonoptimized standard sequence; (2) optimized, that is, increased receive bandwidth sequence (oBW); (3) VAT; (4) combination of oBW and VAT (oBW-VAT); and (5) SEMAC. Two fellowship-trained musculoskeletal radiologists independently evaluated images regarding peri-implant signal void and geometric distortion (a, angle measurement and b, presence of circular shape loss). Statistics included Friedman test and Cochran Q test with Bonferroni correction for multiple comparisons. P values <0.05 were considered to represent statistical significance. RESULTS: All metal-artifact reduction techniques reduced peri-implant signal voids and diminished geometric distortions, with oBW-VAT and SEMAC being most efficient. Compared with nonoptimized sequences, oBW-VAT and SEMAC produced significantly smaller peri-implant signal voids (all P ≤ 0.008) and significantly smaller distortion angles (P ≤ 0.001). Only SEMAC could significantly reduce distortions of circular shapes in the peri-implant frame (P ≤ 0.006). Notably, increasing the number of slice-encoding steps in SEMAC sequences did not lead to a significantly better metal-artifact reduction (all P ≥ 0.257). CONCLUSIONS: The use of basic and advanced methods for metal-artifact reduction at 7-T MRI is feasible and effective. Both a combination of increased receive bandwidth and VAT as well as SEMAC significantly reduce the peri-implant signal void and geometric distortion around metal implants.


Asunto(s)
Artefactos , Imagen por Resonancia Magnética , Estudios de Factibilidad , Imagen por Resonancia Magnética/métodos , Metales , Fantasmas de Imagen
8.
J Ultrasound Med ; 41(4): 827-834, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34086999

RESUMEN

OBJECTIVES: Determine prevalence of increased signal intensity of the lateral collateral ligament (LCL) of the knee on MRI and decreased echogenicity on ultrasound, and compare with cadaveric histologic evaluation. METHODS: After IRB approval of this prospective study with informed consent, patients having knee MRI were additionally evaluated with ultrasound. Signal intensities of LCL on MRI (low, intermediate, high), echogenicity at ultrasound (hyperechoic, hypoechoic, anechoic), and extent of findings were assessed. Descriptive statistics, Wilcoxon signed ranked test, and intraclass correlation coefficient (ICC) were calculated. Two cadaveric knees were imaged with MRI and ultrasound, including histologic LCL evaluation. RESULTS: Seventy-three subjects were included (39 males, 34 females; mean age 48 ± 14 years) with 77 knee examinations. On MRI, low, intermediate, and high signals were present in 21% (16/77), 75% (58/77), and 4% (3/77), respectively. On ultrasound, echogenicity was assessed as hyperechoic, hypoechoic, and anechoic in 62% (48/77), 38% (29/77), and 0% (0/77), respectively. Mean length of increased signal was 8.6 mm (±4.9) on MRI, and 6.5 mm (±4.8) on ultrasound. The ICC showed a good to excellent intermodality reliability (0.735-0.899) without statistically significant difference for interreader measurements (P = .163-.795). Histology evaluation showed transition of ligament fibers to fibrocartilage at its insertion with increased connective tissue mucin corresponding to MRI and ultrasound findings. CONCLUSIONS: Increased signal intensity of the proximal LCL on ultrasound and MRI is common and corresponds to normal connective tissue mucin.


Asunto(s)
Ligamentos Colaterales , Ligamentos Laterales del Tobillo , Adulto , Femenino , Humanos , Articulación de la Rodilla/patología , Ligamentos Laterales del Tobillo/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Ultrasonografía
9.
Eur Radiol ; 31(12): 9436-9445, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34047850

RESUMEN

OBJECTIVES: To test the diagnostic accuracy of a 3D dual-echo steady-state (DESS) sequence at 7-T MRI regarding the detection of chondral calcific deposits of the knee in comparison to 3-T MRI, using CT as cross-sectional imaging reference standard. METHODS: CT and 7-T MRI (DESS) of knee joints in 42 patients with radiographically known chondrocalcinosis (13 of 42 bilateral) were prospectively acquired for all included patients (n = 55 knee joints). Additionally, 3-T MRI (DESS) was performed for 20 of these 55 knee joints. Two fellowship-trained musculoskeletal radiologists scored eight cartilage regions of each knee joint separately regarding presence of cartilage calcification, diagnostic confidence level, and sharpness of calcific deposits. In an explorative subanalysis, micro-CT of the menisci was evaluated after knee arthroplasty in one patient. Diagnostic performance metrics and nonparametric tests were used to compare between modalities. p values < 0.05 were considered to represent statistical significance. RESULTS: Sensitivity for chondrocalcinosis detection was significantly higher for 7-T MRI (100%) compared to 3-T MRI (reader 1: 95.9%, p = 0.03; reader 2: 93.2%, p = 0.002). The diagnostic confidence was significantly higher for both readers at 7 T compared to both 3-T MRI (p < 0.001) and to CT (p = 0.03). The delineation of chondral calcifications was significantly sharper for 7-T compared to both 3-T MRI and CT (p < 0.001, both readers). Micro-CT in one patient suggested that 7-T MRI may potentially outperform standard CT in diagnosing chondral calcifications. CONCLUSION: 3D-DESS imaging at 7-T MRI offers a significantly higher sensitivity in detection of chondral calcific deposits compared to 3-T MRI. KEY POINTS: • 3D dual-echo steady-state (DESS) MRI at 7 T has a higher sensitivity in detection of chondral calcific deposits compared to 3-T MRI (p ≤ 0.03). • 3D DESS MRI at 7 T yields no false-negative cases regarding presence of chondral calcific deposits. • 3D DESS MRI at 7 T offers better delineation and higher diagnostic confidence in detection of chondral calcific deposits compared to 3-T MRI (p < 0.001).


Asunto(s)
Cartílago Articular , Condrocalcinosis , Cartílago Articular/diagnóstico por imagen , Condrocalcinosis/diagnóstico por imagen , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Prospectivos , Tomografía Computarizada por Rayos X
10.
Eur Radiol ; 31(10): 7674-7683, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33860830

RESUMEN

OBJECTIVE: To characterize quadriceps femoris tendon tears on magnetic resonance (MR) imaging regarding tear extent, location, and presence of bony avulsion. MATERIALS AND METHODS: IRB approval was obtained and informed consent was waived for this retrospective case series. Electronic medical records from all patients in our hospital system were searched for keywords: knee MR imaging, and quadriceps tendon rupture or tear. MRI studies were randomized and independently evaluated by two fellowship-trained musculoskeletal radiologists. MR imaging was used to characterize each individual quadriceps tendon as having tendinosis, tear (location, partial versus complete, size, and retraction distance), and bony avulsion. Knee radiographs were reviewed for presence or absence of bony avulsion. Descriptive statistics and inter-reader reliability (Cohen's Kappa and Wilcoxon-signed-rank test) were calculated. RESULTS: Fifty-two patients with 53 quadriceps tears were evaluated (45 males, 7 females; mean age: 51 ± 13 years). The vastus intermedius (VI) tendon more often incurred a partial rather than a complete tear (39.6% vs. 37.7%), while the rectus femoris (RF), vastus medialis (VM), and vastus lateralis (VL) incurred complete tears more commonly (64.2-66%). Subjects with bony avulsion on radiographs had higher-grade tears of the RF, VM, and VL tears (p = 0.020-0.043) but not the VI. Most tendons tore at or immediately proximal to the patella (84.8-93.6%). Gaps in retracted torn tendons measured between 2.3 and 2.7 cm. Inter-reader reliability was substantial to almost perfect (κ = 0.624-0.953). CONCLUSION: Quadriceps femoris tendon tears most commonly involve the RF or VL/VM layers usually in proximity to the patella. A bony avulsion correlates with a more extensive tear. KEY POINTS: • Quadriceps femoris tendon tears most commonly involve the rectus femoris or vastus lateralis/vastus medialis layers. • A rupture of the quadriceps femoris tendon usually occurs in proximity to the patella. • A bony avulsion of the patella correlates with a more extensive tear of the superficial and middle layers of the quadriceps tendon.


Asunto(s)
Músculo Cuádriceps , Tendones , Adulto , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Músculo Cuádriceps/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos
11.
Eur Radiol ; 31(5): 3478-3490, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33119812

RESUMEN

OBJECTIVES: Supine lumbar spine examinations underestimate body weight effects on neuroforaminal size. Therefore, our purpose was to evaluate size changes of the lumbar neuroforamina using supine and upright 3D tomography and to initially assess image quality compared with computed tomography (CT). METHODS: The lumbar spines were prospectively scanned in 48 patients in upright (3D tomographic twin robotic X-ray) and supine (30 with 3D tomography, 18 with CT) position. Cross-sectional area (CSA), cranio-caudal (CC), and ventro-dorsal (VD) diameters of foramina were measured by two readers and additionally graded in relation to the intervertebral disc height. Visibility of bone/soft tissue structures and image quality were assessed independently on a 5-point Likert scale for the 18 patients scanned with both modalities. Descriptive statistics, Wilcoxon's signed-rank test (p < 0.05), and interreader reliability were calculated. RESULTS: Neuroforaminal size significantly decreased at all levels for both readers from the supine (normal intervertebral disc height; CSA 1.25 ± 0.32 cm2; CC 1.84 ± 0.24 cm2; VD 0.88 ± 0.16 cm2) to upright position (CSA 1.12 ± 0.34 cm2; CC 1.78 ± 0.24 cm2; VD 0.83 ± 0.16 cm2; each p < 0.001). Decrease in intervertebral disc height correlated with decrease in foraminal size (supine: CSA 0.88 ± 0.34 cm2; CC 1.39 ± 0.33 cm2; VD 0.87 ± 0.26 cm2; upright: CSA 0.83 ± 0.37 cm2, p = 0.010; CC 1.32 ± 0.33 cm2, p = 0.015; VD 0.80 ± 0.21 cm2, p = 0.021). Interreader reliability for area was fair to excellent (0.51-0.89) with a wide range for cranio-caudal (0.32-0.74) and ventro-dorsal (0.03-0.70) distances. Image quality was superior for CT compared with that for 3D tomography (p < 0.001; κ, CT = 0.66-0.92/3D tomography = 0.51-1.00). CONCLUSIONS: The size of the lumbar foramina is smaller in the upright weight-bearing position compared with that in the supine position. Image quality, especially nerve root delineation, is inferior using 3D tomography compared to CT. KEY POINTS: • Weight-bearing examination demonstrates a decrease of the neuroforaminal size. • Patients with higher decrease in intervertebral disc showed a narrower foraminal size. • Image quality is superior with CT compared to 3D tomographic twin robotic X-ray at the lumbar spine.


Asunto(s)
Disco Intervertebral , Procedimientos Quirúrgicos Robotizados , Humanos , Vértebras Lumbares/diagnóstico por imagen , Región Lumbosacra , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Posición Supina , Rayos X
12.
J Child Orthop ; 14(6): 521-528, 2020 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33343747

RESUMEN

PURPOSE: In situ pinning of mild slipped capital femoral epiphysis (SCFE) results in an aspherical head-neck junction and arthroscopic osteochondroplasty can successfully correct the head-neck junction. However, whether the correction stays stable over at least five years remains unknown. METHODS: In a retrospective and consecutive series, 11 patients with a mean age of 12 years (range, 10 years to 15 years) were included. All patients were treated for mild SCFE with in situ pinning and staged hip arthroscopy correcting the head-neck junction. All patients were assessed clinically and radiographically (radiograph and magnetic resonance imaging (MRI)) pre-operatively, 12 weeks and at least five years' post-operatively. RESULTS: The mean range of motion (ROM) for flexion and internal rotation was stable over time with 100° (sd 4) and 21° (sd 6), respectively at the last follow-up. The mean alpha angle decreased from pre-operative 64° (range 61° to 68°) to 12 weeks post-operative 49° (range 46° to 52°; p = 0.001) and stayed stable over time. New superficial cartilage damage on either the acetabular or femoral side was seen in each three patients. Progressive labral degeneration was present in two patients. CONCLUSION: In situ pinning and staged hip arthroscopy for the correction of mild SCFE is safe, restores normal alpha angles and reveals stable morphological correction at mid-term follow-up. Furthermore, the clinical results were excellent with almost normalized internal hip rotation at mid-term follow-up in patients who had reached adulthood. However, there was some joint deterioration, but without negative impact on subjective and clinical outcome after at least five years. LEVEL OF EVIDENCE: IV.

13.
Skeletal Radiol ; 49(12): 1965-1975, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32556952

RESUMEN

OBJECTIVE: To compare fracture detection, image quality, and radiation dose in patients with distal extremity fractures using 3D tomography and computed tomography (CT). MATERIALS AND METHODS: IRB approval was obtained including informed consent for this prospective study from June to December 2016. Patients diagnosed with an acute fracture at CT were consecutively scanned on the same day using 3D tomography. Anatomical location (effected bone and location within the bone) and morphological characteristics of fractures (avulsion, articular involvement, mono- vs. multifragmented, displacement), visibility of bone/soft tissue structures, and image quality were assessed independently by two blinded readers on a 5-point Likert scale. Dose-length-product (DLP; mGy*cm) was compared between both modalities. Descriptive statistics, Wilcoxon signed rank test (P < 0.05), Student's t test (P < 0.05), and Cohen's kappa (κ) for interreader reliability were calculated. RESULTS: In 46 patients (28 males; 18 females; mean age, 53 ± 20 years) with 28 hand/wrist and 18 foot/ankle examinations, 86 out of 92 fractures were diagnosed with 3D tomography compared with CT. No false-positive finding occurred at 3D tomography. The six missed fractures on 3D tomography were five avulsion fractures of the carpals/metacarpals or tarsals/metatarsals, respectively, and one nondisplaced fracture of the capitate. Interreader agreement of anatomical location and morphological characteristics was substantial to almost perfect for upper (κ = 0.80-0.96) and lower (κ = 0.70-0.97) extremity fractures. Visibility of bone and soft tissue structures and image quality were slightly inferior using 3D tomography compared with CT (upper extremity P < 0.001-0.038 and lower extremity P < 0.001-0.035). DLP of a comparable scan coverage was significantly lower for 3D tomography (P < 0.001) for both upper (3D mean, 19.4 ± 5.9 mGy*cm; estimated CT mean, 336.5 ± 52.2 mGy*cm) and lower extremities (3D mean, 24.1 ± 11.1 mGy*cm; estimated CT mean, 182.9 ± 6.5 mGy*cm). Even the highest DLP with 3D tomography was < 30% of the mean estimated CT dose of a comparable area of coverage. CONCLUSION: Fracture assessment of peripheral extremities is reliable utilizing a low-dose 3D tomography X-ray system, with slightly reduced image quality.


Asunto(s)
Extremidades , Tomografía Computarizada por Rayos X , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Reproducibilidad de los Resultados
14.
PLoS One ; 15(4): e0231508, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32298308

RESUMEN

OBJECTIVE: To determine if findings of "cartilage icing" and chondrocalcinosis on knee radiography can differentiate between gout and calcium pyrophosphate deposition (CPPD). METHODS: IRB-approval was obtained and informed consent was waived for this retrospective study. Electronic medical records from over 2.3 million patients were searched for keywords to identify subjects with knee aspiration-proven cases of gout or CPPD. Radiographs were reviewed by two fellowship-trained musculoskeletal radiologists in randomized order, blinded to the patients' diagnoses. Images were evaluated regarding the presence or absence of cartilage icing, chondrocalcinosis, tophi, gastrocnemius tendon calcification, and joint effusion. Descriptive statistics, sensitivity, specificity, positive and negative predictive values, and accuracy were calculated. RESULTS: From 49 knee radiographic studies in 46 subjects (31 males and 15 females; mean age 66±13 years), 39% (19/49) showed gout and 61% (30/49) CPPD on aspiration. On knee radiographs, cartilage icing showed a higher sensitivity for CPPD than gout (53-67% and 26%, respectively). Chondrocalcinosis also showed a higher sensitivity for CPPD than gout (50-57% versus 5%), with 95% specificity and 94% positive predictive value for diagnosis of CPPD versus gout. Soft tissue tophus-like opacities were present in gout at the patellar tendon (5%, 1/19) and at the popliteus groove in CPPD (15%, 4/27). Gastrocnemius tendon calcification was present in 30% (8/27) of subjects with CPPD, and 5% (1/19) of gout. CONCLUSION: In subjects with joint aspiration-proven crystal disease of the knee, the radiographic finding of cartilage icing was seen in both gout and CPPD. Chondrocalcinosis (overall and hyaline cartilage) as well as gastrocnemius tendon calcification positively correlated with the diagnosis of CPPD over gout.


Asunto(s)
Calcinosis/diagnóstico por imagen , Pirofosfato de Calcio/metabolismo , Cartílago Articular/diagnóstico por imagen , Condrocalcinosis/diagnóstico por imagen , Gota/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Anciano , Calcinosis/diagnóstico , Cartílago Articular/patología , Condrocalcinosis/diagnóstico , Diagnóstico Diferencial , Femenino , Gota/diagnóstico , Humanos , Masculino , Radiografía , Estudios Retrospectivos
15.
Orthop J Sports Med ; 8(2): 2325967119901017, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32110680

RESUMEN

BACKGROUND: Portable ultrasound machines are now common, used for point-of-care applications and needle guidance for percutaneous procedures; however, the effectiveness of portable ultrasound in evaluation of the musculoskeletal system has not been fully assessed. PURPOSE: To prospectively evaluate the use of portable hand-held ultrasound in comparison with conventional cart-based ultrasound in evaluation of the musculoskeletal system. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: In this institutional review board-approved, prospective study, 100 consecutive patients with informed consent were imaged through use of both portable and cart-based ultrasound equipment using 12-5 MHz linear transducers. Agreement in ultrasound diagnosis was documented along with expected clinical changes in management if there was disagreement (definitely no, probably no, uncertain, probably yes, definitely yes). Imaging details of disagreement cases were recorded, and descriptive statistics were calculated. RESULTS: There were 42 male and 58 female patients (mean ± SD age, 53 ± 13 years) imaged over a time period of 20 months. Anatomic areas scanned were the shoulder (n = 30), elbow (n = 11), hand and wrist (n = 15), hip (n = 10), knee (n = 11), foot and ankle (n = 12), and others (n = 11). Scanning with conventional ultrasound revealed abnormality in 92% of patients. Agreement in diagnosis made between portable versus cart-based ultrasound was found in 65% of patients. In the 35% of patients with discordant results, the change in diagnosis resulted in no change in clinical management in 46%, probably no change in 29%, uncertain change in 14%, probable change in 11%, and definite change in 0%. The diagnoses changing management (4%; 4/100) included nondetection of a satellite nodule (n = 1), ganglion cyst (n = 1), hernia (n = 1), and underestimated tendon tear (n = 1). CONCLUSION: When compared with conventional cart-based ultrasound, a musculoskeletal diagnosis using portable hand-held ultrasound was concordant or was discordant without clinical relevance in 96% (96/100) of patients. Knowledge of benefits and limitations of portable hand-held ultrasound will help determine areas where specific types of ultrasound equipment can be used.

16.
Eur J Radiol ; 124: 108842, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32007818

RESUMEN

PURPOSE: To sonographically characterize pseudoerosions and dorsal joint recess and capsule morphology of the hand and wrist in 100 asymptomatic subjects. METHOD: The metacarpal heads, and dorsal aspects of the lunate, triquetrum, and ulna were evaluated for pseudoerosions including measurements and sonographic characterization. The dorsal recesses of the metacarpophalangeal, radiocarpal, and midcarpal joints were also characterized with regards to echogenicity, fibrillar pattern, hyperemia, and measurements. RESULTS: 100 subjects were included (average age 47 years, range 19-82 years; 52% male, 48% female). Pseudoerosions of metacarpophalangeal heads were seen in every subject, in all metacarpal heads, but most commonly the second and third (99% were bilateral, 97% were multiple); 81.5% involved at least three metacarpal heads; 99% were central with maximum depth of 2.6 mm. At the wrist, in 92% of subjects a bilateral pseudoerosion was present at the dorsal triquetrum, lunate, or ulna. Dorsal joint capsules and recesses at the metacarpophalangeal joints were isoechoic to subdermal fat and fibrillar measuring 3.1-6.3 mm in maximal thickness. The dorsal capsules and recesses of the radiocarpal and midcarpal joints were hypoechoic to subdermal fat, non-fibrillar and with maximal thickness of 3.9 and 3.4 mm, respectively. No hyperemia on color Doppler imaging was noted. CONCLUSIONS: Pseudoerosions are common at the dorsal metacarpal heads, lunate, triquetrum, and ulna, which should not be mistaken for true inflammatory erosions. The characteristic appearances of dorsal joint capsules and recesses should not be confused with synovial hypertrophy.


Asunto(s)
Mano/diagnóstico por imagen , Sinovitis , Ultrasonografía/métodos , Articulación de la Muñeca/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Femenino , Humanos , Hueso Semilunar/diagnóstico por imagen , Masculino , Huesos del Metacarpo/diagnóstico por imagen , Persona de Mediana Edad , Cúbito/diagnóstico por imagen , Adulto Joven
17.
J Clin Med ; 8(2)2019 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-30736487

RESUMEN

Infections may constitute a serious complication in patients with chronic lymphocytic leukemia (CLL). New treatment agents including obinutuzumab and ibrutinib have improved the progression-free survival in CLL, and data suggest a similar overall infection risk and a limited risk of opportunistic infections when compared to standard chemo-immunotherapy. Nevertheless, cases of opportunistic infections including non-tuberculous mycobacterial (NTM) in CLL patients have recently been published. We present a case of a 74-year old man with extensive prior CLL treatment history, including most recently obinutuzumab. He developed an abscess of the psoas muscle and inguinal lymphadenopathy. An inguinal node biopsy specimen showed infection with Mycobacterium avium, confirmed by broad-spectrum mycobacterial PCR, M. avium-specific PCR, and mycobacterial culture. This case and our literature review suggest that physicians should be aware of opportunistic infections in patients with CLL. Diagnostic differentiation from CLL disease progression, Richter's transformation to aggressive lymphoma, and secondary malignancy relies on histological and appropriate microbiological studies from biopsy material of affected organs. Infection prophylaxis in CLL should be considered, including vaccinations and intravenous immune globulin replacement.

18.
J Ultrasound Med ; 38(8): 2155-2160, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30592543

RESUMEN

OBJECTIVES: The literature states that wrist ganglion cysts are most commonly dorsal; however, our experience suggests a volar location is more common. The purpose of this study was to identify the locations of ganglion cysts of the wrist as imaged with sonography. METHODS: After Institutional Review Board approval with informed consent waived, retrospective review of wrist sonography reports from January to April 2016 was completed. Only patients who had a comprehensive evaluation that included the dorsal and volar wrist were included. Ultrasound images were reviewed to characterize wrist ganglion cysts. RESULTS: The study group consisted of 98 subjects (78% female, 22% male) (median age, 51 years; range 13-79) with 124 wrist ganglion cysts, where 69% (86 of 124) were volar and 31% (38 of 124) were dorsal. Ganglion cysts were located between the radial artery and flexor carpi radialis in 63% (78 of 124), followed by a dorsal location superficial to the scapholunate ligament in 20% (25 of 124), other dorsal locations in 11% (13 of 124), and other volar locations in 6% (8 of 124). With dorsal ganglion cysts, the scapholunate ligament when imaged appeared normal in 91% (20 of 22). Ganglion cysts were multilocular/multilobular in all subjects. CONCLUSIONS: The most common location for wrist ganglion cysts is in the volar wrist, particularly between the radial artery and flexor carpi radialis tendon, appearing multilocular or multilobular with a mean largest dimension of 1.0 cm. Given the propensity of ganglion cysts to occur at this site, attention to this area when imaging the wrist with sonography or magnetic resonance imaging should be considered.


Asunto(s)
Ganglión/diagnóstico por imagen , Ultrasonografía/métodos , Muñeca/diagnóstico por imagen , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
19.
Invest Radiol ; 53(12): 714-719, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30001256

RESUMEN

OBJECTIVES: The aims of this study were to assess feasibility, image quality, and radiation dose and to estimate the optimal dose protocol for the lumbar spine of cadaveric specimens with different body mass indices (BMIs) in the upright position using a prototype 3-dimensional cone-beam computed tomography (CT) software implemented on a robotic x-ray system and compare with CT. MATERIALS AND METHODS: The lumbar spine of 5 formalin-fixed human cadaveric specimens (BMI, 22-35 kg/m) was prospectively assessed in the upright position using prototype software for 3-dimensional tomography implemented on a robotic x-ray system. Specimens were scanned with varying kilovolt values (70, 81, 90, 100, 109, 121 kV) and thereafter with 80 kV (BMI ≤30 kg/m) and 121 kV (BMI >30 kg/m) and varying dose levels (DLs; 0.278, 0.435, 0.548, 0.696, 0.87, 1.09). Computed tomography data were acquired with a standard clinical protocol. Two independent readers rated visibility of the cortex, endplates, facet joints, trabeculae, neuroforamina, posterior alignment, and spinal canal as well as nerve roots. Radiation dose was measured with a cylindrical CTDI phantom. Descriptive statistics and analysis of variance were used (P < 0.05). RESULTS: Average intraclass correlation was excellent (0.94). The lowest technically possible kilovolt and the highest technically possible DL yielded the best image quality. In specimens with a BMI of 30 kg/m or less, depiction of all structures was good and comparable to CT, except for nerve roots. For specimens with a BMI greater than 30 kg/m, image quality was limited. CONCLUSIONS: Three-dimensional cone-beam CT of the lumbar spine in cadaveric specimens in the upright position is feasible. An optimal dose protocol was estimated. Depiction of osseous structures is comparable to CT in specimens with BMI of 30 kg/m or less. Image quality is limited for soft tissue structures and specimens with BMI greater than 30 kg/m.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Imagenología Tridimensional/métodos , Vértebras Lumbares/diagnóstico por imagen , Adulto , Anciano de 80 o más Años , Índice de Masa Corporal , Cadáver , Estudios de Factibilidad , Femenino , Humanos , Masculino , Fantasmas de Imagen , Postura , Estudios Prospectivos , Dosis de Radiación
20.
Eur Radiol ; 28(11): 4696-4704, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29789912

RESUMEN

OBJECTIVES: To assess the relationship of subchondral bone tracer uptake (BTU) on SPECT/CT and meniscal pathologies on MRI in patients with painful knees. METHODS: Twenty-five patients who had MRI and SPECT/CT within 3 months without knee surgery or grade ≥3 cartilage lesions were prospectively included. Maximum values of each subchondral femorotibial area were quantified and a ratio was calculated in relation to a femoral shaft reference region, which represented the BTU background activity. Meniscal lesions were graded (intact/degeneration/tear) and meniscal extrusion (no/yes) was assessed using MRI by two musculoskeletal radiologists blinded to the SPECT/CT findings. One-tailed Spearman correlations served for statistics (p < 0.05). RESULTS: Knees with meniscal degeneration or tear showed a significantly higher BTU in the medial femorotibial compartment (p = 0.045) when compared to intact menisci. Meniscal degeneration was associated with an increased BTU in the lateral femorotibial compartment; however, this was not statistically significant (p = 0.143). Patients with an extruded meniscus showed significantly higher BTU compared to a non-extruded meniscus (p < 0.020). CONCLUSIONS: Medial femorotibial BTU in SPECT/CT was associated with meniscal pathologies. Highest BTU was found in patients with meniscal tears. SPECT/CT appears to be a useful imaging modality to identify patients with overloading or early osteoarthritis. KEY POINTS: • Meniscal degeneration and tears correlate significantly with increased BTU using SPECT/CT. • Medial meniscus extrusion is associated with an increased BTU in SPECT/CT. • SPECT/CT allows detection of overloading and early osteoarthritis.


Asunto(s)
Artralgia/diagnóstico , Articulación de la Rodilla/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Meniscos Tibiales/diagnóstico por imagen , Osteoartritis de la Rodilla/diagnóstico , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Medronato de Tecnecio Tc 99m/análogos & derivados , Adulto , Anciano , Artralgia/etiología , Artralgia/metabolismo , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/metabolismo , Masculino , Meniscos Tibiales/metabolismo , Menisco , Persona de Mediana Edad , Osteoartritis de la Rodilla/complicaciones , Osteoartritis de la Rodilla/metabolismo , Estudios Prospectivos , Curva ROC , Radiofármacos/farmacocinética , Medronato de Tecnecio Tc 99m/farmacocinética , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...